Note
-
System-stopped/cold
removal
of
the
SPARC
M12-2S
when
all
the
SPARC
M12-2S
units
are
in
the
cold
state
is
not
supported.
Initialization
must
be
done
when
the
SPARC
M12-2S
to
be
removed
and
the
SPARC
M12-2S
where
the
master
XSCF
operates
are
in
the
hot
state.
Use
the
initbb
command
from
the
XSCF
shell
of
the
master
XSCF.
A
SPARC
M12-2S
unit
removed
without
initialization
will
not
operate
normally.
6.6 System-Stopped/Cold
Removal
Workflows
This
section
describes
the
workflows
for
system-stopped/cold
removal
of
the
FRUs
mounted
in
the
SPARC
M12-2/M12-2S,
and
the
workflow
for
system-stopped/cold
removal
of
the
SPARC
M12-2S.
Except
for
system-stopped/cold
removal
of
the
SPARC
M12-2S,
the
described
procedures
are
performed
after
all
the
SPARC
M12-2/M12-2S
units
are
placed
in
the
cold
state,
without
using
the
maintenance
menu.
Note
that,
in
a
building
block
configuration,
you
can
perform
maintenance
using
the
maintenance
menu
when
only
the
SPARC
M12-2S
requiring
maintenance
is
in
the
cold
state.
For
work
procedures
with
the
maintenance
menu,
see
the
procedures
in
"6.4
Inactive/Cold
Removal
Workflows."
To
perform
system-stopped/cold
removal
of
the
SPARC
M12-2S,
be
sure
to
follow
the
procedure
described
in
this
section.
Before
performing
removal
work,
be
sure
to
check
the
notes
on
maintenance
work
in
the
Fujitsu
SPARC
M12
Product
Notes
of
the
XCP
version
used.
Each
of
the
following
sections
puts
together
the
order
of
work
and
the
tasks
for
each
FRU
into
a
table.
For
details
on
each
task,
see
the
reference
shown
in
the
table.
The
following
FRUs
are
subject
to
system-stopped/cold
removal:
â– 
PCIe
card
â– 
HDD/SSD
â– 
CMUU
â– 
Memory
â– 
PCI
expansion
unit
â– 
SPARC
M12-2S
6.6.1 System-Stopped/Cold
Removal
Workflow
of
a
PCIe
Card
Before
removing
a
PCIe
card,
see
"Precautions
for
PCIe
card
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-22
shows
the
workflow
for
system-stopped/cold
removal
of
a
PCIe
card.
Chapter
6
 
FRU
Removal
Workflows 219

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals