Caution
-
When
mounting
a
PSU
in
the
BPU,
make
sure
that
the
PSU
is
oriented
so
that
its
power
connector
is
on
the
left
side.
Mounting
a
PSU
in
the
wrong
orientation
may
damage
the
BPU
or
PSUBP.
Caution
-
Do
not
forcibly
push
the
FANU
when
mounting
it
in
the
FANBPU.
When
mounting
the
FANU,
push
it
at
two
points
at
the
bottom
of
its
front
side.
Pushing
any
points
other
than
the
specified
ones
when
mounting
the
FANU
may
damage
the
FANU
or
FANBPU.
Precautions
for
PSU
replacement
â– 
The
power
control
of
the
SPARC
M12
has
a
redundant
configuration
so
that
the
system
will
continue
to
run
even
if
one
PSU
fails.
However,
avoid
running
the
system
for
a
long
time
in
a
faulty
condition.
Replace
the
failed
PSU.
â– 
When
there
are
multiple
PSUs
to
replace,
replace
them
one
by
one.
If
redundancy
of
the
PSUs
cannot
be
secured,
system-stopped
replacement
must
be
performed.
Precautions
for
FANU
replacement
â– 
The
cooling
fan
of
the
SPARC
M12
has
a
redundant
configuration
so
that
the
system
will
continue
to
run
even
if
one
cooling
fan
of
a
FANU
fails.
However,
avoid
running
the
system
for
a
long
time
with
a
cooling
fan
failed.
Replace
the
FANU
with
the
failed
fan.
â– 
When
there
are
multiple
FANUs
to
replace,
replace
them
one
by
one.
If
redundancy
of
the
FANUs
cannot
be
secured,
system-stopped
replacement
must
be
performed.
Precautions
for
FANBPU
replacement
â– 
Be
sure
to
remove
all
the
FANUs
from
the
FANBPU
before
removing
the
FANBPU.
Precautions
for
HDD/SSD
replacement
â– 
When
the
RAID
volume
is
configured
by
software,
the
configuration
may
need
to
be
changed
on
the
software
before
and
after
the
replacement
of
the
HDD/SSD.
Before
starting
the
work,
be
sure
to
see
the
user
manual
for
the
software
being
used.
Precautions
for
PCIe
card
replacement
â– 
To
perform
active
replacement
of
a
PCIe
card,
the
PCIe
to
be
replaced
must
support
PCI
Hot
Plug.
Before
performing
active
replacement,
see
"Appendix
B
Cards
That
Support
PCI
Hot
Plug
and
Dynamic
Reconfiguration"
in
the
Fujitsu
SPARC
M12
PCI
Card
Installation
Guide.
â– 
Before
performing
active
replacement
of
a
PCIe
card
having
a
multipath
I/O
Chapter
7
 
FRU
Maintenance
Precautions 229

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals