Table
8-4
  
Predictive
Self-repairing
Messages
Displayed
Output Description
EVENT-TIME:
Thu
Apr
19
10:48:39
JST
2012 EVENT-TIME:
Diagnosis
time
stamp
PLATFORM:
ORCL,SPARC64-X,
CSN:
PP115300MX,
HOSTNAME:
4S-LGA12-D0
PLATFORM:
Description
of
the
server
where
the
error
occurred
SOURCE:
eft,
REV:
1.16 SOURCE:
Information
about
the
diagnosis
engine
used
to
identify
the
error
EVENT-ID:
fcbb42a5-47c3-c9c5-f0b0-f782d69afb01 EVENT-ID:
Universally
unique
event
ID
for
this
error
DESC:
The
diagnosis
engine
encountered
telemetry
from
the
listed
devices
for
which
it
was
unable
to
perform
a
diagnosis
-
ereport.io.pciex.rc.epkt@chassis0/cpuboard0/chip0/hostbridge0/
pciexrc0
class
and
path
are
incompatible.
DESC:
Basic
description
of
the
error
AUTO-RESPONSE:
Error
reports
have
been
logged
for
examination.
AUTO-RESPONSE:
Corrective
actions
taken
(if
any)
by
the
system
to
alleviate
any
subsequent
problems
IMPACT:
Automated
diagnosis
and
response
for
these
events
will
not
occur.
IMPACT:
Description
of
assumed
impact
from
the
fault
REC-ACTION:
Use
'fmadm
faulty'
to
provide
a
more
detailed
view
of
this
event.
Use
'fmdump
-eV'
to
view
the
unexpected
telemetry.
Please
refer
to
the
associated
reference
document
at
http://support.
oracle.com/msg/SUNOS-8000-J0
for
the
latest
service
procedures
and
policies
regarding
this
diagnosis.
REC-ACTION:
Brief
description
of
the
corrective
action
that
the
system
administrator
needs
to
take
Table
8-5
  
FRU
Status
Display Description
Normal Normal
status
Faulted The
unit
has
stopped
due
to
a
fault.
Degraded The
unit
has
a
fault
somewhere
but
continues
to
operate.
Deconfigured The
unit
is
degraded
as
a
result
of
the
fault
or
degradation
of
another
unit.
Maintenance Maintenance
work
is
being
performed
with
the
replacefru,
addfru,
or
initbb
command.
(3)
Checking
the
FRU
status
Check
the
system
hardware
configuration
and
status
of
each
FRU.
Table
8-5
shows
the
meaning
of
each
FRU
status
displayed
as
a
command
execution
result.
Checking
the
hardware
configuration
and
status
of
each
FRU
To
check
the
hardware
configuration
and
FRU
status
for
the
entire
system,
log
in
to
the
XSCF
shell,
and
execute
the
showhardconf
command.
An
asterisk
(*)
placed
at
the
Chapter
8
 
Preparation
for
Maintenance 253

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals