EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #361 background imageLoading...
Page #361 background image
[This
operation
may
take
up
to
45
minute(s)]
(progress
scale
reported
in
seconds)
0.....
30.....
60.....
90.....
120.....
150.....
180.....
210.....
240.....
270.....
300.....
done
 
Do
you
want
to
start
to
diagnose
BB#0?[s:start|c:cancel]
:
Do
you
want
to
start
to
diagnose
BB#0?[s:start|c:cancel]
:
s
Note
-
If
the
CMUL
has
been
replaced,
select
"c"
(cancel)
in
step
2
to
end
the
replacefru
command.
Then,
confirm
that
the
combination
of
the
CMUL
and
XSCFU
types
is
correct
by
using
the
showhardconf
command.
After
that,
run
a
diagnosis
with
the
testsb
command.
For
details
on
the
showhardconf
and
testsb
commands,
see
"10.5.1
Diagnosing
the
SPARC
M12
Hardware."
Note
-
The
hardware
diagnosis
in
step
2
does
not
cover
PCIe
cards,
HDDs/SSDs,
and
PCI
expansion
units.
In
the
following
cases,
select
"c"
(cancel)
in
step
2
to
end
the
replacefru
command.
Then,
run
a
diagnosis
with
the
testsb
command.
For
details
on
the
testsb
command,
see
"10.5.1
Diagnosing
the
SPARC
M12
Hardware."
-
You
have
performed
maintenance
on
a
PCIe
card,
HDD/SSD,
or
PCI
expansion
unit
with
the
SPARC
M12-2S
released.
-
You
have
performed
CMUU,
memory,
BPU,
or
PSUBP
maintenance
in
the
SPARC
M12-2/
M12-2S
with
a
PCIe
card
mounted.
Note
-
For
the
XSCF
DUAL
control
cable
and
the
XSCF
BB
control
cable,
select
"c"
(cancel)
in
step
2.
Diagnostic
tests
for
BB#0
have
started.
Initial
diagnosis
is
about
to
start,
Continue?[y|n]
:
y
PSB#00-0
power
on
sequence
started.
0....end
Initial
diagnosis
started.
[7200sec]
0.....
30.....
60.....
90.....120.....150.....180.....210.....240...../
270.....300.....330.....360.....390.....420.....450.....480.....510.....-
540.end
2.
Diagnose
the
hardware
of
the
SPARC
M12-2S
that
has
undergone
maintenance.
When
the
following
message
appears,
enter
"s."
If
you
cancel
the
diagnosis,
Unknown
will
be
displayed
under
Status
in
step
4.
 
When
the
following
message
appears,
check
that
the
diagnosis
target
is
BB#0
and
then
enter
"y"
to
start
the
hardware
diagnosis.
During
the
hardware
diagnosis,
the
following
is
displayed
to
let
you
check
the
status
of
the
diagnosis.
Chapter
10
 
Setting
Up
the
System 339

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals