4-19
  
Active/Cold
Replacement
Procedure
of
the
PSUBP
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
from
a
logical
domain
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
7Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state,
and
removing
the
PSUBP
from
the
SPARC
M12-2S
"18.4
Removing
the
BPU
and
PSUBP"
8
Installing
the
PSUBP
in
the
SPARC
M12-2S,
and
placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
(*1)
"18.5
Installing
the
BPU
and
PSUBP"
9 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
10 Diagnosing
the
SPARC
M12-2S
requiring
maintenance
(*2)
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
11 Diagnosing
the
XBU
and
crossbar
cable
of
the
SPARC
M12-2S
requiring
maintenance
"10.5.2
Diagnosing
the
XBU
and
Crossbar
Cable"
12 Confirming
that
there
is
no
problem
with
the
replacement
PSUBP
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
13 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
14 Incorporating
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
into
a
logical
domain
"10.7
Incorporating
I/O
Resources
Into
a
Logical
Domain"
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
202392

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals