DR
sequence
finished
(sequence#=2,
message#=3)
..
Processing
of
the
incoming
DR
request
by
the
LDoms
Manager
is
pendingIncoming
DR
request
is
being
processed
by
the
LDoms
ManagerDR
sequence
started
(sequence#=3,
message#=2)
DR
sequence
finished
(sequence#=3,
message#=2)
.end
Unconfigured
PSB
from
PPAR.
PSB
power
off
sequence
started.
[1200sec]
0.....
30.....
60.....
90.....120.....150...end
Operation
has
completed.
Note
-
You
may
need
to
assign
command
options
depending
on
how
the
DR
is
used
and
the
logical
domain
system
configuration.
For
details
on
command
options,
see
"3.1.16
Deleting
a
System
Board
From
a
Building
Block
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
XSCF>
showresult
0
Note
-
For
information
on
the
action
to
take
if
the
deleteboard
command
ends
abnormally,
see
"3.1.16
Deleting
a
System
Board
From
a
Building
Block
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
XSCF>
showboards
-va
PSB
R
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
----
-
------------
-----------
----
----
----
-------
--------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
01-0
*
00(01)
Assigned
n
n
n
Passed
Normal
XSCF>
11.
Check
the
end
code
of
the
deleteboard
command.
If
the
end
code
is
not
0,
the
deleteboard
command
ended
abnormally.
Eliminate
the
cause
of
the
failure,
and
then
execute
the
deleteboard
command
again.
 
In
the
following
example,
"0"
is
returned
as
the
end
status,
so
you
can
see
that
the
execution
of
the
deleteboard
command
has
completed
correctly.
12.
Confirm
that
the
SPARC
M12-2S
of
BB-ID#01
has
been
powered
off
and
that
the
system
board
is
in
the
pool
state.
Since
the
SPARC
M12-2S
has
been
released
with
the
disconnect
option,
incorporation
into
PPAR
ID#00
is
reserved.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023304

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals