Maintenance/Replacement
Menu
Please
select
the
chassis
including
replaced
FRU.
 
No.
FRU
Status
---
-------------------
--------------
1
/BB#0
Normal
2
/BB#1
Unmount
3
/BB#2
Unmount
4
/BB#3
Unmount
------------------------------------------------------------------------------
Select
[1-4|c:cancel]
:
1
------------------------------------------------------------------------------
Maintenance/Replacement
Menu
Please
select
the
BB
or
a
type
of
FRU
to
be
replaced.
1.
BB
itself
2.
FAN
(Fan
Unit)
3.
PSU
(Power
Supply
Unit)
4.
XSCFU
(Extended
System
Control
Facility
Unit)
5.
Crossbar
cable
------------------------------------------------------------------------------
Select
[1-5|c:cancel]
:
3
------------------------------------------------------------------------------
Maintenance/Replacement
Menu
Please
select
a
FRU
to
be
replaced.
No.
FRU
Status
---
-------------------
--------------
1
/BB#0/PSU#0
Faulted
2
/BB#0/PSU#1
Normal
3
/BB#0/PSU#2
Normal
4
/BB#0/PSU#3
Normal
------------------------------------------------------------------------------
Select
[1-4|b:back]
:
1
You
are
about
to
replace
BB#0/PSU#0.
Do
you
want
to
continue?[r:replace|c:cancel]
:
r
3.
With
a
number
key,
select
the
FRU
requiring
maintenance.
Enter
"1"
to
perform
maintenance
on
the
PSU
of
the
SPARC
M12-2
(BB#0).
4.
With
a
number
key,
select
the
FRU
requiring
maintenance.
Enter
"3"
to
perform
maintenance
on
the
PSU
of
the
SPARC
M12-2.
5.
With
a
number
key,
select
the
faulty
FRU.
Enter
"1"
since
a
fault
has
been
confirmed
in
PSU#0
of
BB#0.
6.
Confirm
that
the
selected
FRU
is
displayed,
and
then
enter
"r".
Chapter
9
 
Releasing
FRUs
From
the
System 315