XSCF>
showlogs
error
XSCF>
showhardconf
SPARC
M12-2S;
+
Serial:PZ51649002;
Operator_Panel_Switch:Service;
+
System_Power:On;
System_Phase:Cabinet
Power
On;
Partition#0
PPAR_Status:Running;
BB#00
Status:Normal;
Role:Master;
Ver:3015h;
Serial:PZ51649002;
+
FRU-Part-Number:CA20369-B17X
005AC/7341758
;
+
Power_Supply_System:
;
+
Memory_Size:256
GB;
CMUL
Status:Normal;
Ver:2101h;
Serial:PP164804GG
;
+
FRU-Part-Number:CA07855-D301
A5
/7341541
;
+
Memory_Size:128
GB;
Type:
C
;
CPU#0
Status:Normal;
Ver:4242h;
Serial:00070051;
+
Freq:4.250
GHz;
Type:0x30;
+
Core:12;
Strand:8;
MEM#00A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04E6E;
+
Type:83;
Size:16
GB;
MEM#01A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04ED1;
+
Type:83;
Size:16
GB;
MEM#02A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C0510D;
+
Type:83;
Size:16
GB;
MEM#03A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04F51;
+
Type:83;
Size:16
GB;
MEM#04A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04E6F;
+
Type:83;
Size:16
GB;
MEM#05A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04F50;
+
Type:83;
Size:16
GB;
MEM#06A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C04EFB;
+
Type:83;
Size:16
GB;
MEM#07A
Status:Normal;
+
Code:ce8002M393A2K40BB1-CRC
00-31C051AE;
+
Type:83;
Size:16
GB;
CMUU
Status:Normal;
Ver:2101h;
Serial:PP164804GN
;
+
FRU-Part-Number:CA07855-D451
A4
/7341568
;
+
Memory_Size:128
GB;
Type:
C
;
4.
Check
the
hardware
configuration.
Enter
the
showhardconf
command
to
check
that
the
replacement
FRU
has
been
incorporated
into
the
system.
If
there
is
an
error,
an
asterisk
(*)
appears
at
the
beginning
of
the
line
on
which
the
corresponding
FRU
name
is
shown.
 
If
the
XSCFU
has
been
replaced,
confirm
that
the
combination
of
the
XSCFU
and
CMUL
types
is
correct.
For
details,
see
Table
8-2
in
"8.1.6
Checking
FRU
Information."
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023352