Page #514 background imageLoading...
Page #514 background image
Date:
Sep
08
14:10:25
JST
2016
Code:
80002100-007d20007811007811-150650000130049a00313000
Status:
Alarm
Occurred:
Sep
08
14:10:12.925
JST
2016
FRU:
/BB#1/XBU#0/CBL#0R
,/BB#1/XBU#0,/BB#0/XBU#0
Msg:
XB-XB
interface
link-up
error
found
in
the
crossbar
cable
connected
to
port
number
0R
of
XBU#0
mounted
in
BB#1.
From
the
above
error
message
and
"Appendix
A
Lists
of
Cable
Connections
in
a
Building
Block
Configuration,"
identify
the
port
number
at
the
other
end
of
the
connection
of
the
target
crossbar
cable.
In
this
example,
"BB00-XBU0-0R"
is
the
port
number
at
the
other
end.
2.
Affix
labels
to
the
crossbar
cable.
The
replacement
crossbar
cable
comes
with
the
labels
shown
in
Figure
19-3.
Write
the
connected
port
on
these
labels.
For
the
crossbar
cable,
use
LABEL-A
to
LABEL-D.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023492

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals