Table
3-11
  
Applicable
Types
of
Maintenance
in
FRU
Replacement
for
the
SPARC
M12-2S
(Multiple-BB
Configuration)
-:
Not
applicable
FRU Active
Replacement
Inactive
Replacement
System-Stopped
Replacement
Hot
Cold
(*1)
Hot
Cold
(*1)
Hot Cold
XSCFU OK
OK
(*2)
OK
OK
(*3)
OK OK
(*4)
  
(*5)
PCIe
card OK
(*6) OK OK OK OK OK
(*4)
PSU OK
(*7) OK OK OK OK OK
(*4)
FANU OK
(*7) OK OK OK OK OK
(*4)
FANBPU - OK - OK - OK
(*4)
HDD/SSD OK
(*8) OK OK OK OK OK
(*4)
HDDBPU - OK - OK - OK
(*4)
OPNL - OK - OK - OK
(*4)
CMU - OK - OK - OK
(*4)
Memory - OK - OK - OK
(*4)
BPU - OK - OK - OK
(*4)
PSUBP - OK - OK - OK
(*4)
XBU - - - OK - OK
(*4)
Crossbar
cable - - - OK - OK
(*9)
XSCF
DUAL
control
cable - OK
(*10)
-OK
(*10)
-OK
(*9)
XSCF
BB
control
cable - OK
(*10)
-OK
(*10)
-OK
(*9)
PCI
expansion
unit
(chassis) OK
(*6) OK OK OK OK OK
*1
The
replacefru(8)
command
is
used
for
maintenance.
For
this
purpose,
select
BB
in
the
maintenance
menu.
*2
If
the
XSCFU
requiring
maintenance
is
not
running,
perform
active/hot
replacement.
*3
If
the
XSCFU
requiring
maintenance
is
not
running,
perform
inactive/hot
replacement.
*4
The
replacefru(8)
command
is
used
for
maintenance.
For
this
purpose,
select
BB
in
the
maintenance
menu.
Alternatively,
without
using
the
replacefru(8)
command,
you
can
replace
a
FRU
after
placing
every
SPARC
M12-2S
in
the
building
block
configuration
into
the
cold
state.
*5
If
the
XSCFU
requiring
maintenance
is
not
running,
perform
system-stopped/hot
replacement.
Alternatively,
place
every
SPARC
M12-2S
in
the
building
block
configuration
into
the
cold
state,
and
replace
the
XSCFU.
*6
Maintenance
is
performed
using
the
SR-IOV
function,
dynamic
reconfiguration
function
for
PCIe
devices,
and
PCI
Hot
Plug
function.
*7
This
is
possible
only
if
the
target
FRU
is
in
a
redundant
configuration.
*8
This
is
possible
only
for
the
mirror
volumes
(RAID1
and
RAID1E)
when
the
HDD/SSD
used
as
the
boot
device
is
being
replaced.
*9
The
FRU
can
be
replaced
only
when
every
SPARC
M12-2S
in
the
building
block
configuration
is
in
the
cold
state.
*10
The
XSCF
DUAL
control
cable
or
XSCF
BB
control
cable
requiring
replacement
is
connected
to
the
XSCFU.
If
the
READY
LED
of
the
XSCFU
is
off,
place
every
SPARC
M12-2S
in
the
building
block
configuration
into
the
cold
state,
and
replace
the
cable.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
202356

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals