UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 179
18
Power-Saving Mode
0=Normal mode
1 = Power-Saving Mode
(Eco-Mode)
1 20-02-10
19
CTA Data Communication Mode
Select 0 if the dip switch settings
on the CTA Adapter are set to PC
connection (1=on, 2~8=off) or
select 1 if the DIP switches are set
to printer connection (1~2=on,
3~8=off).
0=CTI Mode
1 = Non Procedural Mode
(Non-SCS)
0 15-02-20
20
Baud Rate for CTA Port
Select the baud rate used by the
CTA Adapter.
0 = 4800
1 = 9600
2 = 19200
2 15-02-19
21
Virtual Extension Access Mode
(when idle Virtual Extension key
pressed)
Determine whether a Virtual
Extension (VE) should function as
a DSS key or a Virtual Extension.
When DSS (0) is selected, the key
functions as a DSS key to the
extension and for incoming calls to
that extension. When Outgoing (1)
is selected, the key functions as a
virtual extension and can be used
for incoming and outgoing calls.
When Ignore (2) is selected, the
key functions can receive incoming
calls only.
0 = DSS
1 = Outgoing (OTG)
2 = Ignore
2
22
Multiple Incoming From
Intercom and Trunk
If enabled, this affects how a
Hotline key lights, based on the
setting in Program 22-01-01. If
22-01-01 is set to 1 for trunk
priority, the Hotline key lights solid
when a trunk call rings in. If
22-01-01 is set to 0 for intercom
priority, the Hotline key does not
light for incoming trunk calls, but
lights solid for intercom calls.
If 15-02-22 is disabled, Hotline
keys light solid for any incoming
calls regardless of the setting in
Program 22-01-01.
0 = Disable
1 = Enable
1 22-01-01
Item
No.
Item Input Data Default
Related
Program