8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 259
[5030] TOSHIBA Remote monitoring system error (HTTP communication error)
[50FF] TOSHIBA Remote monitoring system error (eBR2 internal error)
[5110] Toner cartridge detection error
[5410] MFP registration error / TOSHIBA Global remote monitoring system error
[5411] MFP registration lock error / TOSHIBA Global remote monitoring system error
Classification Error item
Communication error with external
application
An error in the HTTP communication
Check item Measures
Setting • Check the URL for communication.
• Check that the valid IP address is assigned to connect to
the server.
Classification Error item
MFP internal error A fatal error occurred in the MFP
Check item Measures
Setting Restart the MFP, and then try again.
Classification Error item
TopAccess related error
Check item Measures
Setting • Check if the toner cartridge is installed properly.
• Check if the toner cartridge detection sensor operates
properly.
Classification Error item
MFP registration error An invalid registration by accessing a cloud server using a
valid serial No. of the equipment has been performed. Or
database in the cloud server has been damaged.
Check item Measures
Setting of a cloud server Retry the registration. Contact the administrator of the cloud
server.
Classification Error item
MFP registration error Data to be sent to a cloud server from the equipment has
been damaged or incorrect authentication data have been
sent. Or TOSHIBA equipment which has not been supported
by the cloud server has been tried to be registered.
Check item Measures
None Contact the administrator of the cloud server.