8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 39
8061 Secure Update to Primary IPv4
DDNS failed.
Secure primary DDNS update
error
P. 8-277
8062 Secure Update to Secondary
IPv4 DDNS failed
Secure secondary DDNS update
error
P. 8-277
8063 Secure Update to Primary IPv6
DDNS failed.
Secure primary DDNS update
error
P. 8-277
8064 Secure Update to Secondary
IPv6 DDNS failed
Secure secondary DDNS update
error
P. 8-277
8065 IPv6 Update to Primary DDNS
failed.
IPv6 primary DDNS update error P. 8-277
8066 IPv6 Update to Secondary DDNS
failed.
IPv6 secondary DDNS update
error
P. 8-277
8067 IPv4 Update to Primary DDNS
failed.
IPv4 primary DDNS update error P. 8-277
8068 IPv4 Update to Secondary DDNS
failed.
IPv4 secondary DDNS update
error
P. 8-277
8069 Invalid TSIG/SIG(0) Key file
uploaded
This message is displayed when
the key file for SIG(0) or TSIG is
invalid.
P. 8-277
8101 Wireless association with Access
point failure
Wireless association with Access
point failure
P. 8-277
8102 Unable to contact Access point MFP not able to contact the
Access point with the specified
SSID
P. 8-277
8103 Certificate verification Failure Wireless Certificate verification
failure
P. 8-278
8111 SNMP set request failure An error occurred during SNMP
data writing.
P. 8-278
8112 SNMP communication failure SNMP communication failed. P. 8-278
8121 Domain - General Failure during
Authentication
Domain Authentication Error -
General Failure during
Authentication
P. 8-278
8122 Domain - Invalid Username or
Password
Domain Authentication Error -
Invalid Username or Password
P. 8-278
8123 Domain - Server not present in
Network
Domain Authentication Error -
Server not present in Network
P. 8-279
8124 Domain - User account is
disabled on Server
Domain Authentication Error -
User account is disabled on
Server
P. 8-279
8125 Domain - User account has
expired and cannot be used for
logon
Domain Authentication Error -
User account has expired and
cannot be used for logon
P. 8-279
8126 Domain - User account is locked
and cannot be used for logon
Domain Authentication Error -
User account is locked and
cannot be used for logon
P. 8-279
8127 Domain - Invalid logon hours for
the User
Domain Authentication Error -
Invalid logon hours for the User
P. 8-279
8128 Active Directory Domain - Clock
Skew error due to difference in
Time between Server and MFP
Active Directory Domain
Authentication Error - Clock
Skew error due to difference in
Time between Server and MFP
P. 8-280
Error code
Message displayed in the
TopAccess screen
Contents Troubleshooting