Table
9-10
  
Procedure
for
Dynamically
Releasing
an
HDD/SSD
From
Oracle
Solaris
Step Operation
Description
Execution
Location
Command
Used
1
(*1) Checking
the
device
path
of
the
target
HDD/SSD
primary
domain
Root
domain
Oracle
Solaris
11
#
diskinfo
Oracle
Solaris
10
(*2)
#
diskinfo
-ap
2
(*1) Checking
the
BB-ID
of
the
SPARC
M12-2S
that
houses
the
target
HDD/SSD
XSCF
shell
Oracle
Solaris
11
XSCF>
showhardconf
Oracle
Solaris
10
XSCF>
showboards
-a
3 Checking
the
mounting
location
of
the
target
HDD/SSD
(Ap_Id)
primary
domain
Root
domain
#
cfgadm
-al
4 Releasing
the
target
HDD/SSD
from
the
Oracle
Solaris
device
configuration
primary
domain
Root
domain
#
cfgadm
-c
unconfigure
<Ap_Id>
5 Confirming
that
you
can
remove
the
target
HDD/SSD
primary
domain
Root
domain
#
cfgadm
-al
6Having
the
CHECK
LED
(amber)
of
the
HDD/SSD
released
from
the
Oracle
Solaris
device
configuration
blink
(*3)
(*4)
primary
domain
Root
domain
#
cfgadm
-x
led=fault,mode=blink
<
Ap_Id
>
7
(*5) Turning
off
the
CHECK
LED
primary
domain
Root
domain
#
cfgadm
-x
led=fault,mode=off
<Ap_Id>
*1
When
using
only
one
SPARC
M12-2
or
SPARC
M12-2S,
skip
this
operation.
*2
Check
the
device
path
of
the
target
HDD/SSD
and
the
LSB
number
of
the
SPARC
M12-2S
that
houses
the
HDD/SSD,
according
to
"Appendix
A
Lists
of
SPARC
M12/M10
System
Device
Paths"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
System
Operation
and
Administration
Guide.
*3
Before
removing
the
HDD/SSD,
confirm
that
the
CHECK
LED
(amber)
is
blinking.
*4
When
removing
a
hard
disk,
pull
it
out
slightly
from
its
slot,
wait
for
10
seconds,
and
then
remove
it
from
the
slot.
*5
When
replacing
the
HDD/SSD,
incorporate
it
into
the
Oracle
Solaris
device
configuration
and
then
turn
off
the
CHECK
LED.
For
details,
see
Table
2-22.
#
diskinfo
D:devchassis-path
c:occupant-compdev
------------------------------
---------------------
/dev/chassis/SYS/BB0/HDD0
-
/dev/chassis/SYS/BB0/HDD1
-
/dev/chassis/SYS/BB0/HDD2
-
/dev/chassis/SYS/BB0/HDD3
-
/dev/chassis/SYS/BB0/HDD4/disk
c5t50000393D82954D6d0
/dev/chassis/SYS/BB0/HDD5
-
/dev/chassis/SYS/BB0/HDD6
-
/dev/chassis/SYS/BB0/HDD7/disk
c5t50000393B81B2446d0
The
following
example
executes
the
commands
for
enabling
the
removal
of
an
HDD/SSD
by
using
the
PCI
Hot
Plug
function.
Confirming
the
HDD/SSD
to
be
released
[Oracle
Solaris
11
with
SRU
11.4.27.82.1
or
later
applied]
1.
Use
the
diskinfo
command
to
check
the
device
pathname
and
BB-ID.
Chapter
9
 
Releasing
FRUs
From
the
System 291

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals