XSCF>
XSCF>
showhardconf
SPARC
M12-2S;
+
Serial:PZ51618004;
Operator_Panel_Switch:Locked;
+
System_Power:On;
System_Phase:Cabinet
Power
On;
Partition#0
PPAR_Status:Running;
BB#00
Status:Normal;
Role:Master;
Ver:300ch;
Serial:PZ51618004;
+
FRU-Part-Number:CA20369-B17X
003AB/9999999
;
+
Power_Supply_System:
;
+
Memory_Size:256
GB;
CMUL
Status:Normal;
Ver:1101h;
Serial:PP16170119
;
+
FRU-Part-Number:CA07855-D201
A1
/9999999
;
+
Memory_Size:128
GB;
Type:
C
;
(Omitted)
BB#01
Status:Normal;
Role:Standby;
Ver:300ch;
Serial:PZ51617007;
+
FRU-Part-Number:CA20369-B17X
003AB/9999999
;
+
Power_Supply_System:
;
+
Memory_Size:256
GB;
CMUL
Status:Normal;
Ver:1101h;
Serial:PP1617010X
;
+
FRU-Part-Number:CA07855-D201
A1
/9999999
;
+
Memory_Size:128
GB;
Type:
C
;
(Omitted)
BB#02
Status:Normal;
Role:Slave;
Ver:300ch;
Serial:PZ51617011;
+
FRU-Part-Number:CA20369-B17X
003AB/9999999
;
+
Power_Supply_System:
;
+
Memory_Size:128
GB;
CMUL
Status:Normal;
Ver:1101h;
Serial:PP1617010U
;
+
FRU-Part-Number:CA07855-D201
A1
/9999999
;
+
Memory_Size:128
GB;
Type:
C
;
CPU#0
Status:Normal;
Ver:4241h;
Serial:00000056;
+
Freq:4.250
GHz;
Type:0x30;
+
Core:12;
Strand:8;
(Omitted)
7.
Check
the
hardware
configuration
information.
From
the
master
XSCF,
check
the
hardware
configuration
of
the
SPARC
M12-2S
added
to
the
building
block
configuration,
by
using
the
showhardconf
command.
If
there
is
a
hardware
error,
an
asterisk
(*)
appears
in
front
of
the
corresponding
FRU
name.
Remove
the
cause
of
the
error
by
using
the
replacefru
or
other
appropriate
command,
before
proceeding
with
the
system
operation.
8.
Assign
the
CPU
core
resources.
Assign
the
CPU
core
resources
of
the
added
SPARC
M12-2S
to
physical
partitions.
If
you
cannot
assign
the
CPU
core
resources,
check
whether
a
CPU
Activation
key
is
registered.
For
details,
see
"Chapter
5
CPU
Activation"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
System
Operation
and
Administration
Guide.