EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #358 background imageLoading...
Page #358 background image
270.....300.....330....end
Initial
diagnosis
has
completed.
PSB
power
off
sequence
started.
[1200sec]
0.....
30.....
60...end
PSB
powered
off.
PSB#02-0
power
on
sequence
started.
0.....
30...end
Initial
diagnosis
started.
[2
/
2]
[7200sec]
0.....
30.....
60.....
90.....120.....150.....180.....210.....240...../
270..end
Initial
diagnosis
has
completed.
PSB
power
off
sequence
started.
[1200sec]
0.....
30.....
60...end
PSB
powered
off.
PSB
Test
Fault
----
-------
--------
02-0
Passed
Normal
done
 
 
------------------------------------------------------------------------------
Maintenance/Addition
Menu
Please
select
the
chassis
including
added
FRU.
No.
FRU
Status
---
-------------------
--------------
1
/BB#0
Normal
2
/BB#1
Normal
3
/BB#2
Normal
4
/BB#3
Unmount
------------------------------------------------------------------------------
Select
[1-4|c:cancel]
:
c
(*9)
*6
Enter
"f"
to
start
the
operation
of
incorporating
the
SPARC
M12-2S
into
the
building
block
configuration.
*7
Check
whether
to
perform
the
hardware
diagnosis
on
the
added
SPARC
M12-2S.
If
the
added
SPARC
M12-2S
has
a
PCIe
card
mounted,
cancel
the
hardware
diagnosis,
and
temporarily
complete
the
incorporation
process.
If
you
cancel
the
hardware
diagnosis,
see
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
and
perform
the
diagnosis
before
incorporating
the
added
SPARC
M12-2S
into
the
physical
partition.
*8
Enter
"y"
to
start
the
hardware
diagnosis.
*9
Enter
"c"
to
end
the
addfru
command.
XSCF>
showboards
-a
-v
PSB
R
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
----
-
------------
-----------
----
----
----
-------
--------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
01-0
00(01)
Assigned
y
y
y
Passed
Normal
02-
0
SP
Available
n
n
n
Passed
Normal
 
6.
Check
the
status
of
the
building
block
configuration.
From
the
master
XSCF,
check
the
status
of
the
building
block
configuration
by
using
the
showboards
command.
If
you
cancel
the
hardware
diagnosis
in
step
5,
"Unknown"
is
displayed
in
the
Test
column.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
January
2023336

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals