cfgadm
-a
Ap_Id
Type
Receptacle
Occupant
Condition
BB#0-PCI#0
pci-pci/hp
connected
configured
ok
#
cfgadm
-x
led=attn,mode=off
BB#0-PCI#0
#
Note
-
Dynamic
reconfiguration
of
the
PCIe
endpoint
device
is
supported
by
the
combination
of
XCP
2230
or
later
and
Oracle
VM
Server
for
SPARC
3.1.1.1
or
later.
#
cfgadm
-al
Ap_Id
Type
Receptacle
Occupant
Condition
(Omitted)
c2
scsi-sas
connected
configured
unknown
c2::dsk/c2t50000394281B50C6d0
disk
connected
configured
unknown
c2::es/ses0
ESI
connected
configured
unknown
c2::smp/expd0
smp
connected
configured
unknown
c3
scsi-sas
connected
unconfigured
unknown
c4
scsi-sas
connected
unconfigured
unknown
c5
fc
connected
unconfigured
unknown
7.
Turn
off
the
ATTENTION
LED.
The
following
example
turns
off
the
ATTENTION
LED
of
BB#-PCI#0.
Hereinafter,
assign
the
I/O
resources
of
the
PCIe
card
to
the
guest
domain
or
I/O
domain.
Assign
the
I/O
resources
as
appropriate
for
the
I/O
configuration
of
the
target
logical
domain,
by
referencing
"10.7
Incorporating
I/O
Resources
Into
a
Logical
Domain."
When
incorporating
the
HDD/SSD
1.
Log
in
to
Oracle
Solaris.
Log
in
to
the
logical
domain
(control
domain
or
root
domain)
into
which
the
HDD/SSD
will
be
incorporated.
2.
Mount
the
HDD/SSD
in
the
SPARC
M12-2/M12-2S.
Mount
the
HDD/SSD
in
the
SPARC
M12-2/M12-2S,
by
using
the
procedure
described
in
"Chapter
15
Maintaining
Internal
Storage."
After
mounting
the
HDD/SSD,
wait
until
the
READY
LED
on
the
HDD/SSD
starts
to
blink
and
then
comes
on.
3.
Check
the
status
of
the
mounted
HDD/SSD.
In
Oracle
Solaris
on
the
control
domain
or
root
domain,
execute
the
cfgadm
command
with
the
-al
option
to
check
the
status
of
the
mounted
HDD/SSD.
If
the
HDD/SSD
has
failed
to
be
incorporated
and
configured
is
not
shown,
perform
step
4.
The
following
example
checks
that
the
HDD/SSD
whose
Ap_Id
is
c2::dsk/
c2t500003294281B50C6d0
is
mounted.
Chapter
10
 
Setting
Up
the
System 359

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals