Caution
-
When
connecting
the
crossbar
cable,
do
not
hold
the
pull-tab
but
hold
the
connector
part
to
insert
it
into
the
port
for
the
connection,
and
push
in
the
connector
part.
If
you
hold
the
pull-tab
when
connecting
the
crossbar
cable,
it
may
become
impossible
to
remove
the
cable
from
the
XBU.
Caution
-
A
loose
crossbar
cable
connection
may,
on
rare
occasions,
cause
an
error
due
to
poor
connection.
After
connecting
a
crossbar
cable,
push
it
in
again
so
that
it
is
tightly
in
place
to
prevent
any
improper
connection.
Do
not
hold
only
the
cable
when
performing
the
work
at
this
time.
Otherwise,
the
cable
may
bend
out
of
shape.
For
details,
see
step
4
in
"19.4
Installing
the
Crossbar
Cable."
Note
-
The
destination
port
for
the
XBU
is
described
on
a
label
affixed
to
the
crossbar
cable.
Check
the
label
first
and
connect
the
cable
to
the
port
of
the
XBU.
For
crossbar
cable
connection
destinations,
see
"4.3
Connecting
Crossbar
Cables"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide.
Figure
18-32
  
Installing
the
XBU
9.
Connect
the
crossbar
cables.
Connect
the
crossbar
cables
to
the
XBU.
For
details,
see
"19.4
Installing
the
Crossbar
Cable."
10.
Install
the
PCICS.
Install
the
PCICS
in
the
server,
and
then
secure
the
PCICS.
For
details,
see
"12.4
Installing
a
PCIe
Card."
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
January
2023484