12
52
Module
3.1
Applied Registra
t
ion
Registration
Figure 13
In Cyclone Navigator select ScanWorld
Station-003: SW-003
Open
ModelSpace 1 View 1
Navigate to the target (review overview drawing for orientation)
Pick a point near the center of the target
Choose
Create Object | Fit to Cloud | Black/White Target
Figure 14
Enter “3” as
Target ID
of the target.
Next a windows comes up asking to which ControlSpaces the vertex should be
copied. Leave both ControlSpaces checked on. (Figure 14)
Visually inspect the fitting result
Exit with
OK.
Each ScanWorld has a master ControlSpace and in addition a subordinate
ControlSpace for each Registration. In this case the vertex has been copied to
both the master ControlSpace (ControlSpace) and the one belonging to
Registration1 (ControlSpace (Registration1))
Please refer to chapter 7.2 of this module for a more in depth review of
ControlSpaces.