Notice how all disabled targets (the status displays
Off)
now show even an bigger error – from
30 mm to 33 mm. They are not influencing our registration anymore, hence the algorithm is not
trying to minimize these errors as well.
Therefore the increase in error confirm the suspicion that there was an error in the total station
data of target 11 and that disabling it was the correct thing to do.
Selected constraints can also be deleted from the current registration by marking
them in the Constraint List and Edit | Delete.
Ensure to recalculate via Registration | Register every time the constraints are
altered.
Figure 63
Once happy with the results, finish the registration process:
Execute
Registration | Create ScanWorld/ Freeze Registration
Go to
Registration | Create and Open ModelSpace
6.5 Final Quality Check
Figure 64
After the Registration has been finalized it is recommended to perform a final quality assurance
of the alignment of all the ScanWorlds.
For details on the workflow please refer to section
4.6 Registration Diagnostics