40
52
Module
3.1
Applied Registra
t
ion
Registration
Figure 61
Improving results
The maximum remaining Error between targets is 18mm, mostly referring to target 11.
Since this error has increased with including the survey data it might indicate a general problem
with this target. We will therefore disable this target from the calculation to see if this improves
the overall accuracy of our network.
In the
Constraint List
select all constraints where target 11 from the survey
data is involved. (sort by Error)
Figure 62
From the menu to
Constraint | Disable
The
Status
of the constraints should now be
OFF
Recalculate the registration without using these constraints via
Registration |
Register
Sort by error clicking in the
Error
field in
Constraint List
tab