Figure 61
Improving results
The maximum remaining Error between targets is 18mm, mostly referring to target 11.
Since this error has increased with including the survey data it might indicate a general problem
with this target. We will therefore disable this target from the calculation to see if this improves
the overall accuracy of our network.
•
In the
Constraint List
select all constraints where target 11 from the survey
data is involved. (sort by Error)
Figure 62
•
From the menu to
Constraint | Disable
•
The
Status
of the constraints should now be
OFF
•
Recalculate the registration without using these constraints via
Registration |
Register
•
Sort by error clicking in the
Error
field in
Constraint List
tab