EasyManua.ls Logo

Lenze i550 - Page 679

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Designaon Default seng Category Data type Factor A M
0x2631:004
(P400.04)
Funcon list: Reset fault Digital input 2 [12] general U8 1 P -
0x2631:005
(P400.05)
Funcon list: Acvate DC braking Not connected [0] general U8 1 P -
0x2631:006
(P400.06)
Funcon list: Start forward (CW) Not connected [0] general U8 1 PC -
0x2631:007
(P400.07)
Funcon list: Start reverse (CCW) Not connected [0] general U8 1 PC -
0x2631:008
(P400.08)
Funcon list: Run forward (CW) Not connected [0] general U8 1 PC -
0x2631:009
(P400.09)
Funcon list: Run reverse (CCW) Not connected [0] general U8 1 PC -
0x2631:010
(P400.10)
Funcon list: Jog foward (CW) Not connected [0] general U8 1 PC -
0x2631:011
(P400.11)
Funcon list: Jog reverse (CCW) Not connected [0] general U8 1 PC -
0x2631:012
(P400.12)
Funcon list: Acvate keypad control Not connected [0] general U8 1 P -
0x2631:013
(P400.13)
Funcon list: Reverse rotaonal direcon Digital input 3 [13] general U8 1 PC -
0x2631:014
(P400.14)
Funcon list: Acvate AI1 setpoint Not connected [0] general U8 1 P -
0x2631:015
(P400.15)
Funcon list: Acvate AI2 setpoint Not connected [0] general U8 1 P -
0x2631:016
(P400.16)
Funcon list: Acvate keypad setpoint Not connected [0] general U8 1 P -
0x2631:017
(P400.17)
Funcon list: Acvate network setpoint Not connected [0] general U8 1 P -
0x2631:018
(P400.18)
Funcon list: Acvate preset (bit 0) Digital input 4 [14] general U8 1 P -
0x2631:019
(P400.19)
Funcon list: Acvate preset (bit 1) Digital input 5 [15] general U8 1 P -
0x2631:020
(P400.20)
Funcon list: Acvate preset (bit 2) Not connected [0] general U8 1 P -
0x2631:021
(P400.21)
Funcon list: Acvate preset (bit 3) Not connected [0] general U8 1 P -
0x2631:022
(P400.22)
Funcon list: Acvate setpoint via HTL input Not connected [0] general U8 1 P -
0x2631:023
(P400.23)
Funcon list: MOP setpoint up Not connected [0] general U8 1 P -
0x2631:024
(P400.24)
Funcon list: MOP setpoint down Not connected [0] general U8 1 P -
0x2631:025
(P400.25)
Funcon list: Acvate MOP setpoint Not connected [0] general U8 1 P -
0x2631:026
(P400.26)
Acvate segment setpoint (bit 0) Not connected [0] Sequencer U8 1 P -
0x2631:027
(P400.27)
Acvate segment setpoint (bit 1) Not connected [0] Sequencer U8 1 P -
0x2631:028
(P400.28)
Acvate segment setpoint (bit 2) Not connected [0] Sequencer U8 1 P -
0x2631:029
(P400.29)
Acvate segment setpoint´(bit 3) Not connected [0] Sequencer U8 1 P -
0x2631:030
(P400.30)
Run/abort sequence Not connected [0] Sequencer U8 1 PC -
0x2631:031
(P400.31)
Start sequence Not connected [0] Sequencer U8 1 PC -
0x2631:032
(P400.32)
Next sequence step Not connected [0] Sequencer U8 1 PC -
* Default seng depending on the size.
Appendix
Parameter aribute list
679

Table of Contents

Other manuals for Lenze i550

Related product manuals