Address Designaon Default seng Category Data type Factor A M
0x2631:033
(P400.33)
Pause sequence Not connected [0] Sequencer U8 1 PC -
0x2631:034
(P400.34)
Suspend sequence Not connected [0] Sequencer U8 1 PC -
0x2631:035
(P400.35)
Stop sequence Not connected [0] Sequencer U8 1 PC -
0x2631:036
(P400.36)
Abort sequence Not connected [0] Sequencer U8 1 PC -
0x2631:037
(P400.37)
Funcon list: Acvate network control Not connected [0] general U8 1 P -
0x2631:039
(P400.39)
Funcon list: Acvate ramp 2 Not connected [0] general U8 1 P -
0x2631:040
(P400.40)
Funcon list: Load parameter set Not connected [0] general U8 1 PC -
0x2631:041
(P400.41)
Funcon list: Select parameter set (bit 0) Not connected [0] general U8 1 PC -
0x2631:042
(P400.42)
Funcon list: Select parameter set (bit 1) Not connected [0] general U8 1 PC -
0x2631:043
(P400.43)
Funcon list: Acvate fault 1 Not connected [0] general U8 1 P -
0x2631:044
(P400.44)
Funcon list: Acvate fault 2 Not connected [0] general U8 1 P -
0x2631:045
(P400.45)
Funcon list: Deacvate PID controller Not connected [0] general U8 1 P -
0x2631:046
(P400.46)
Funcon list: Set process controller output to 0 Not connected [0] general U8 1 P -
0x2631:047
(P400.47)
Funcon list: Inhibit process controller I-component Not connected [0] general U8 1 P -
0x2631:048
(P400.48)
Funcon list: Acvate PID inuence ramp Constant TRUE [1] general U8 1 P -
0x2631:049
(P400.49)
Funcon list: Open holding brake Not connected [0] general U8 1 PC -
0x2631:050
(P400.50)
Select sequence (bit 0) Not connected [0] Sequencer U8 1 PC -
0x2631:051
(P400.51)
Select sequence (bit 1) Not connected [0] Sequencer U8 1 PC -
0x2631:052
(P400.52)
Select sequence (bit 2) Not connected [0] Sequencer U8 1 PC -
0x2631:053
(P400.53)
Select sequence (bit 3) Not connected [0] Sequencer U8 1 PC -
0x2631:054
(P400.54)
Funcon list: Posion counter reset Not connected [0] general U8 1 P -
0x2631:055
(P400.55)
Funcon list: Acvate UPS operaon Not connected [0] general U8 1 P -
0x2632:001
(P411.01)
Inversion of digital inputs: Digital input 1 Not inverted [0] general U8 1 P -
0x2632:002
(P411.02)
Inversion of digital inputs: Digital input 2 Not inverted [0] general U8 1 P -
0x2632:003
(P411.03)
Inversion of digital inputs: Digital input 3 Not inverted [0] general U8 1 P -
0x2632:004
(P411.04)
Inversion of digital inputs: Digital input 4 Not inverted [0] general U8 1 P -
0x2632:005
(P411.05)
Inversion of digital inputs: Digital input 5 Not inverted [0] general U8 1 P -
0x2632:006
(P411.06)
Inversion of digital inputs: Digital input 6 Not inverted [0] Appl. I/O U8 1 P -
0x2632:007
(P411.07)
Inversion of digital inputs: Digital input 7 Not inverted [0] Appl. I/O U8 1 P -
0x2633:001 Digital input debounce me: Digital input 1 1 ms general U8 1 P -
* Default seng depending on the size.
Appendix
Parameter aribute list
680