Address Designaon Default seng Category Data type Factor A M
0x2637:012
(P431.12)
Analog input 2: Max torque value 100.0 % general I16 10 P -
0x2639:001
(P440.01)
Analog output 1: Output range 0 ... 10 VDC [1] general U8 1 P -
0x2639:002
(P440.02)
Analog output 1: Funcon Output frequency [1] general U8 1 P -
0x2639:003
(P440.03)
Analog output 1: Min. signal 0 general I32 1 P -
0x2639:004
(P440.04)
Analog output 1: Max. signal 1000 general I32 1 P -
0x263A:001
(P441.01)
Analog output 2: Output range 0 ... 10 VDC [1] Appl. I/O U8 1 P -
0x263A:002
(P441.02)
Analog output 2: Funcon Motor current [5] Appl. I/O U8 1 P -
0x263A:003
(P441.03)
Analog output 2: Min. signal 0 Appl. I/O I32 1 P -
0x263A:004
(P441.04)
Analog output 2: Max. signal 1000 Appl. I/O I32 1 P -
0x2640:001
(P415.01)
HTL input sengs: Minimum frequency 0.0 Hz general I32 10 P -
0x2640:002
(P415.02)
HTL input sengs: Maximum frequency 0.0 Hz general I32 10 P -
0x2640:003
(P415.03)
HTL input sengs: Minimum motor frequency 0.0 Hz general I16 10 P -
0x2640:004
(P415.04)
HTL input sengs: Maximum motor frequency Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
general I16 10 P -
0x2640:005
(P415.05)
HTL input sengs: Minimum PID setpoint 0.00 PID unit general I16 100 P -
0x2640:006
(P415.06)
HTL input sengs: Maximum PID setpoint 100.00 PID unit general I16 100 P -
0x2640:007
(P415.07)
HTL input sengs: Minimum torque setpoint 0.0 % general I16 10 P -
0x2640:008
(P415.08)
HTL input sengs: Maximum torque setpoint 100.0 % general I16 10 P -
0x2640:009
(P415.09)
HTL input sengs: Filter me constant 10 ms general U16 1 P -
0x2641:001
(P416.01)
HTL input monitoring: Minimum frequency thresh-
old
0.0 Hz general I32 10 P -
0x2641:002
(P416.02)
HTL input monitoring: Minimum delay threshold 5.0 s general U16 10 P -
0x2641:003
(P416.03)
HTL input monitoring: Maximum frequency thresh-
old
0.0 Hz general I32 10 P -
0x2641:004
(P416.04)
HTL input monitoring: Maximum delay threshold 5.0 s general U16 10 P -
0x2641:005
(P416.05)
HTL input monitoring: Monitoring condions Below minimum fre-
quency [1]
general U8 1 P -
0x2641:006
(P416.06)
HTL input monitoring: Error response No response [0] general U8 1 P -
0x2642:001
(P115.01)
HTL input diagnoscs: Input frequency x.x Hz (Read only) general I32 10 - t
0x2642:002
(P115.02)
HTL input diagnoscs: Frequency setpoint x.x Hz (Read only) general I16 10 - t
0x2642:003
(P115.03)
HTL input diagnoscs: PID setpoint x.xx PID unit (Read only) general I16 100 - t
0x2642:004
(P115.04)
HTL input diagnoscs: Torque setpoint x.x % (Read only) general I16 10 - t
* Default seng depending on the size.
Appendix
Parameter aribute list
683