Address Designaon Default seng Category Data type Factor A M
0x2946:007
(P340.07)
Speed limitaon: Actual upper speed limit x.x Hz (Read only) general I16 10 - -
0x2946:008
(P340.08)
Speed limitaon: Actual lower speed limit x.x Hz (Read only) general I16 10 - -
0x2947:001 ...
0x2947:017
Inverter characterisc: Value y1 ... Value y17 0.00 V * MCTRL U16 100 P -
0x2948:001 Torque setpoint: Actual torque setpoint x.x % (Read only) general I16 10 - -
0x2948:002
(P336.02)
Torque setpoint: ramp me 1.0 s general U16 10 P -
0x2949:001
(P337.01)
Torque limit source selecon: Posive torque limit
source
Max torque [0] general U8 1 P -
0x2949:002
(P337.02)
Torque limit source selecon: Negave torque limit
source
(-) Max torque [0] general U8 1 P -
0x2949:003
(P337.03)
Torque limit source selecon: Actual posive torque
limit
x.x % (Read only) general I16 10 - -
0x2949:004
(P337.04)
Torque limit source selecon: Actual negave tor-
que limit
x.x % (Read only) general I16 10 - -
0x29C0:001 Gain 59.68 A/Vs * MCTRL U32 100 P -
0x29C0:002 Reset me 45.5 ms * MCTRL U16 10 P -
0x29E0:001 Field weakening controller sengs: Gain (ASM) 0.000 Vs/V * MCTRL U32 1000 P -
0x29E0:002 Field weakening controller sengs: Reset me
(ASM)
1478.3 ms * MCTRL U32 10 P -
0x29E0:003 Field weakening controller sengs: Reset me
(PSM)
800.0 ms * MCTRL U32 10 P -
0x29E1 Field weakening controller Field limitaon 100.00 % MCTRL U16 100 OP r
0x29E2 DC-bus lter me 25.0 ms MCTRL U16 10 P -
0x29E3 Motor voltage lter me 25.0 ms MCTRL U16 10 P -
0x29E4
(P354.00)
Voltage reserve range 5 % general U8 1 P -
0x2B00
(P302.00)
V/f characterisc shape Linear [0] general U8 1 PC -
0x2B01:001
(P303.01)
V/f shape data: Base voltage 230 V * MCTRL U16 1 P -
0x2B01:002
(P303.02)
V/f shape data: Base frequency Device for 50-Hz mains:
50 Hz
Device for 60-Hz mains:
60 Hz *
MCTRL U16 1 P -
0x2B01:003
(P303.03)
V/f shape data: Midpoint voltage 0 V MCTRL U16 1 P -
0x2B01:004
(P303.04)
V/f shape data: Midpoint frequency 0 Hz MCTRL U16 1 P -
0x2B08:001
(P333.01)
V/f Imax controller: Gain 0.284 Hz/A * MCTRL U32 1000 P -
0x2B08:002
(P333.02)
V/f Imax controller: Reset me 2.3 ms * MCTRL U32 10 P -
0x2B09:001
(P315.01)
Slip compensaon: Gain 100.00 % general I16 100 P -
0x2B09:002
(P315.02)
Slip compensaon: Filter me 100 ms general U16 1 P -
0x2B0A:001
(P318.01)
Gain 150 % MCTRL I16 1 P -
0x2B0A:002
(P318.02)
Filter me 30 ms MCTRL U16 1 P -
0x2B0B Frequency setpoint x.x Hz (Read only) general I16 10 O t
0x2B0C
(P319.00)
Override eld weakening 0.0 Hz general I16 10 P -
0x2B0D:001
(P330.01)
VFC-ECO: Minimum voltage 20 % MCTRL I16 1 P -
* Default seng depending on the size.
Appendix
Parameter aribute list
689