Service Parts Disassembly 8-85
Toner Cartridge Holder (PL7.2.1~4) 
The procedure for removal of the Toner Cartridge Holder is the same for all colors. 
Note
To control Toner spillage, do not disconnect the Auger Tube from the Developer 
Frame Assembly unless absolutely necessary to perform the repair. Remove the 
HVPS to access the Auger Tube connections.
1. Remove the CRUM Reader (page 8-83).
Note
With the CRUM Reader removed, any of the four Toner Cartridge Holders are 
available for removal and servicing. 
2. Disconnect the appropriate Toner Motor and No Toner Sensor connections from 
the holder being removed. 
3. Remove the harness from the clamp mounted directly above the motor.
4. Remove the screw (metal, 6 mm) that secures the end of the Toner Cartridge 
Holder to the Toner Cartridge Holder Assembly.
5. Release the T-shaped hook near the Toner Motor to release the Toner Cartridge 
Holder from the assembly.
6. Disconnect the Auger Tube.