A-16 Phaser 6300/6350 Color Laser Printer Service Manual
Clutch Tests - Tests the functionality of the clutches.
Registration Clutch
Tray 1 (M P T) Tu r n
Clutch (PL4.2.9)
Tray 3 Turn Clutch
Tray 4 Turn Clutch
Tray 5 Turn Clutch
Clutch is On
Clutch is Off
Audible verification of Clutch
functionality. You should hear a
continuous clicking until the test is
ended by pressing Cancel.
Solenoid Tests - Tests the functionality of the solenoids.
Tray [1 (MPT)][2][3]
[4][5] Feed Solenoid
Solenoid is On
Solenoid is Off
Audible verification of the Solenoid
function.
Maintenance - Cleans the Intermediate Transfer Unit within the Imaging Unit.
Clean Imaging Unit
IDT 1
Clean Imaging Unit
IDT 2
Printing..... Printing displays during the IDT
cleaning cycle.
The test continuously cycles paper
until Cancel is pressed.
NVRAM Access - This menu lets you read, set or reset the following values:
PostScript NVRAM
Reset
Resetting PostScript NVRAM...
Are you sure? Yes / NO
Restores the printer’s setup values
to their factory defaults.
MCU NVRAM
Store/Restore
Save Engine NVRAM
Restore Engine NVRAM
Saves printer installation date,
printer page count, imaging unit
life count, transfer roller life count
to Image Processor Board.
Restores previously saved data to
the Engine Control Board.
Toner Install Dates Black Toner Install Date
Cyan Toner Install Date
Magenta Toner Install Date
Yellow Toner Install Date
Allows toner cartridge install dates
to be viewed, or changed.
Toner CRUM Check (<Color> Not) Genuine Xerox Toner Verifies that genuine Xerox toner is
installed in the printer.
CRU Life Reset Resets life count of selected item.
Confirmed Reset or Unconfirmed
Reset
Transfer Roller Life
Reset value: 0 Units: Pages
Black Developer (K) Life
Reset value: 0 Units: Revolutions
Cyan Developer (C) Life
Reset value: 0 Units: Revolutions
Magenta Developer (M) Life Reset
value: 0 Units: Revolutions
Yellow Developer (Y) Life
Reset value: 0 Units: Revolutions
Sets Transfer Roller life to unused
and resets the installation date to
the current date indicated by the
printer.
NOTE: Toner CRUM life counts
cannot be modified.
Resets component life count.