EasyManua.ls Logo

Dell Force10 MXL Blade - Show Interfaces

Dell Force10 MXL Blade
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interfaces | 259
Command
History
Example
Figure 14-27. show config (Bulk Configuration) Command Example
show interfaces
Display information on a specific physical interface or virtual interface.
Syntax
show interfaces interface
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Use this show interfaces command for details on a specific interface. Use the show interfaces
stack-unit
command for details on all interfaces on the designated stack unit.
On the MXL Switch, the show interface output displays incorrect rate information details over time for
link monitoring when the rate-interval is configured for 5 seconds. Dell Force10 recommends using
higher rate-intervals such as 15 to 299 seconds to minimize the errors seen.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
FTOS(conf)#interface range tengigabitethernet 1/1 - 2
FTOS(conf-if-range-tengig-1/1-2)#show config
!
interface TenGigabitEthernet 1/1
no ip address
switchport
no shutdown
!
interface TenGigabitEthernet 1/2
no ip address
switchport
no shutdown
FTOS(conf-if-range-tengig-1/1-2)#
interface
Enter one of the following keywords and slot/port or number information:
For a Loopback interface, enter the keyword
loopback followed by a number from 0 to
16383.
For the management interface, enter the keyword
ManagementEthernet followed by
the slot/port information. The slot range is 0 to 1 and the port range is 0.
For a Null interface, enter the keywords
null 0.
For a Port Channel interface, enter the keyword
port-channel followed by a number:
Range: 1 to 128
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet followed by
the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by the slot/port
information.
For a VLAN interface, enter the keyword
vlan followed by a number from 1 to 4094.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
Note: In the CLI output, the power value will be rounded to a 3-digit value. For receive/
transmit power that is less than 0.000, an snmp query will return the corresponding dbm value
even though the CLI displays as 0.000.

Table of Contents

Other manuals for Dell Force10 MXL Blade

Related product manuals