514 | Remote Monitoring (RMON)
www.dell.com | support.dell.com
show rmon hc-alarm
Display the contents of RMON High-Capacity Alarm Table.
Syntax
show rmon hc-alarm [index] [brief] 
Parameters
 
Defaults
none
Command Modes
EXEC
Command History
Example 1
Figure 27-6.  show rmon hc-alarm brief Command Example 
Example 2
Figure 27-7.  show rmon hc-alarm index Command Example 
show rmon history
Display the contents of the RMON Ethernet History table.
Syntax
show rmon history [index] [brief] 
Parameters
 
Defaults
none
index
(OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON High-Capacity 
Alarm Table in an easy-to-read format.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
FTOS#show rmon hc-alarm brief
index           SNMP OID
--------------------------------------------------------------------
1               1.3.6.1.2.1.1.3
2               1.3.6.1.2.1.1.3
3               1.3.6.1.2.1.1.3
4               1.3.6.1.2.1.1.3
5               1.3.6.1.2.1.1.3
FTOS#
FTOS#show rmon hc-alarm 1
RMON high-capacity alarm entry 1
    object: 1.3.6.1.2.1.1.3
    sample interval: 5
    sample type: absolute value.
    value: 185638
    alarm type: rising or falling alarm.
    alarm rising threshold value: positive.
    rising threshold: 1001, RMON event index: 1
    alarm falling threshold value: positive.
    falling threshold: 999, RMON event index: 6
    alarm sampling failed 0 times.
    alarm owner: 1
    alarm storage type: non-volatile.
    alarm status: OK
FTOS#
index
(OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet 
History table in an easy-to-read format.