Uplink Failure Detection (UFD) | 645
36
Uplink Failure Detection (UFD)
Overview
Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if used
with network interface controller (NIC) teaming, automatic recovery from a failed link.
Commands
The UFD commands described in this chapter are:
• clear ufd-disable
• debug uplink-state-group
• description
• downstream
• downstream auto-recover
• downstream disable links
• enable
• show running-config uplink-state-group
• show uplink-state-group
• uplink-state-group
• upstream
clear ufd-disable
Re-enable one or more downstream interfaces on the switch/router that are in a UFD-disabled error
state so that an interface can send and receive traffic.
Syntax
clear ufd-disable {interface interface | uplink-state-group group-id}