EasyManua.ls Logo

Dell Force10 MXL Blade - Uplink Failure Detection (UFD); Overview; Commands

Dell Force10 MXL Blade
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Uplink Failure Detection (UFD) | 645
36
Uplink Failure Detection (UFD)
Overview
Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if used
with network interface controller (NIC) teaming, automatic recovery from a failed link.
Commands
The UFD commands described in this chapter are:
clear ufd-disable
debug uplink-state-group
description
downstream
downstream auto-recover
downstream disable links
enable
show running-config uplink-state-group
show uplink-state-group
uplink-state-group
upstream
clear ufd-disable
Re-enable one or more downstream interfaces on the switch/router that are in a UFD-disabled error
state so that an interface can send and receive traffic.
Syntax
clear ufd-disable {interface interface | uplink-state-group group-id}

Table of Contents