Stacking Commands | 613
Example
Figure 33-1. reset stack-unit Command Example on the Stack Standby Unit
Related
Commands
show redundancy
Display the current redundancy configuration (status of automatic reboot configuration on stack
management unit).
Syntax
show redundancy
Command Modes
EXEC
EXEC Privilege
Command
History
FTOS# show system brief
Stack MAC : 00:1e:c9:f1:00:7b
Reload Type : jump-start [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-------------------------------------------------------------------------------
0 Management online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
1 Standby online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
2 Member online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
3 Member online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
4 Member online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
5 Member online MXL-10/40GbE MXL-10/40GbE 9-1-0-853 56
FTOS#reset stack-unit ?
<0-5> Unit number id
FTOS#reset stack-unit 0
% Error: Reset of master unit is not allowed.
FTOS(standby)#reset stack-unit 3
% Error: Reset of stack units from standby is not allowed.
<<no reset of other member
FTOS(standby)#
FTOS(standby)#reset stack-unit 1<<Resetting standby unit success!
00:02:50: %STKUNIT4-S:CP %CHMGR-5-STACKUNIT_RESET: Stack unit 4 being reset
00:02:50: %STKUNIT4-S:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 4 down - reset
00:02:50: %STKUNIT4-S:CP %IFMGR-1-DEL_PORT: Removed port: TenGig 4/1-48
FTOS#rebooting
U-Boot 1.1.4 (June 6 2012 - 00:00:04)
<<Resetting master not allowed
reload Reboots FTOS.
redundancy disable-auto-reboot Resets the designated stack member.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module