612 | Stacking Commands
www.dell.com | support.dell.com
Usage
Information
When the command is given as redundancy disable-auto-reboot stack-unit, it prevents the MXL 10/
40GbE switch stack management unit and standby unit from rebooting if they fail.
When a particular unit number in the range 0-5 is issued as part of the CLI, it prevents that particular
unit from rebooting upon failure.
When members is issued as part of the CLI, all the units part of the stack are prevented from rebooting
upon failure.
The unit does not reboot until it is manually rebooted.
Related
Commands
redundancy force-failover stack-unit
Force the backup unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults
Not enabled
Command Modes
EXEC Privilege
Command
History
reset stack-unit
Reset any designated stack member except the management unit (master unit).
Syntax
reset stack-unit 0-5 hard
Parameters
Default
none
Command Modes
EXEC Privilege
Command
History
Usage
Information
Resetting the management unit is not allowed (an error message is displayed if you try to do so).
Resetting is a soft reboot, including flushing the forwarding tables.
You can run this command directly on the stack standby unit (Standby Master) to reset the standby.
You cannot reset any other unit from the standby unit.
show redundancy Displays the current redundancy status.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
0-5
Enter the stack member unit identifier of the stack member to reset.
hard
Reset the stack unit if the unit is in a problem state.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module