Stacking Commands | 611
33
Stacking Commands
Overview
For more information about using the MXL 10/40GbE Switch stacking feature, refer
to the “Stacking MXL 10/40GbE Switches” chapter in the FTOS Configuration
Guide.
Commands
The commands described in this chapter are used for managing the stacking of MXL 10/40GbE switch
systems. The stacking commands are:
• redundancy disable-auto-reboot
• redundancy force-failover stack-unit
• reset stack-unit
• show redundancy
• show system stack-ports
• show system stack-unit stack-group
• stack-unit stack group
• stack-unit priority
• stack-unit provision
• stack-unit renumber
redundancy disable-auto-reboot
Prevent the MXL 10/40GbE switch stack unit from rebooting if they fail.
Syntax
redundancy disable-auto-reboot stack-unit [0-5 | members]
To return to the default, use the no redundancy disable-auto-reboot stack-unit [0-5 |
members] command.
Default
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command
History
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module