Interfaces | 285
Parameters
 
Defaults
none
Command Modes
EXEC
Command
History
Example
Figure 14-44.  show tdr tengigabitethernet Command Example 
Table 14-12.  TDR Test Status 
Usage
Information
If the TDR test has not been run, an error messages is generated: 
%Error: Please run the TDR test first
Related
Commands
 
interface
Enter the keyword TenGigabitEthernet followed by the slot/port information 
for the 100/1000 Ethernet interface.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
Status Definition
OK Status: Terminated
TDR test is complete, no fault is detected on the 
cable, and the test is terminated
Length: 92 (+/- 1) meters, Status: Shorted 
A short is detected on the cable. The location, in 
this example is 92 meters, of the short is accurate 
to plus or minus one meter.
Length: 93 (+/- 1) meters, Status: Open
An opening is detected on the cable. The location, 
in this example is 93 meters, of the open is 
accurate to plus or minus one meter.
Status: Impedance Mismatch There is an impedance mismatch in the cables.
FTOS#show tdr tengigabitethernet 10/47
Time since last test: 00:00:02
  Pair A, Length: OK Status: Terminated
  Pair B, Length: 92 (+/- 1) meters, Status: Short
  Pair C, Length: 93 (+/- 1) meters, Status: Open
  Pair D, Length: 0 (+/- 1) meters, Status: Impedance Mismatch
tdr-cable-test Runs the TDR test.