60 | Control and Monitoring
www.dell.com | support.dell.com
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Information
Figure 4-13 shows the output of the show environment fan command as it appears prior to FTOS 7.8.1.0.
Example
Figure 4-13. show environment all Command Example
Example
Figure 4-14. show environment stack-unit Command Example
Example
Figure 4-15. show environment thermal-sensor Command Example
all
Enter the keyword all to view all components.
stack-unit unit-id Enter the keyword stack-unit followed by the unit-id to display information on
a specific stack member. Range: 0 to 5.
thermal sensor
Enter the keyword thermal-sensor to view all components.
Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module
FTOS#show environment all
-- Unit Environment Status --
Unit Status Temp Voltage
---------------------------------------------------------------------------
* 0 online 47C ok
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
0 50 52 53 53 54 48 57 57 53
56
FTOS#
FTOS#show environment stack-unit 0
-- Unit Environment Status --
Unit Status Temp Voltage
---------------------------------------------------------------------------
0* online 49C ok
* Management Unit
FTOS#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
--------------------------------------------------------------------------------
----------------
0 50 52 53 53 54 48 57 57 53
56
* Management Unit
FTOS#