698 | SNMP Traps
www.dell.com | support.dell.com
RESV NONE NONE
N/A
CHM_MIN_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature
CHM_MIN_ALRM_TEMP_CLR ENVMON TEMP
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d temperature is within threshold of %dC)
CHM_MAJ_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (%s temperature reaches or exceeds threshold of %dC)
CHM_MAJ_ALRM_TEMP_CLR ENVMON TEMP
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (%s %d temperature is within threshold of %dC)
TME_TASK_SUSPEND ENVMON NONE
%TME-2-TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s
TME_TASK_TERM ENVMON NONE
%TME-2-ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s
CHM_CPU_THRESHOLD ENVMON NONE
%CHMGR-5-CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)
CHM_CPU_THRESHOLD_CLR ENVMON NONE
%CHMGR-5-CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)
CHM_MEM_THRESHOLD ENVMON NONE
%CHMGR-5-MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)
CHM_MEM_THRESHOLD_CLR ENVMON NONE
%CHMGR-5-MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)
MACMGR_STN_MOVE ENVMON NONE
%MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d
VRRP_BADAUTH PROTO NONE
%RPM1-P:RP2 %VRRP-3-VRRP_BAD_AUTH: vrid-1 on TenGig 11/12 rcvd pkt with authentication type mismatch.
%RPM1-P:RP2 %VRRP-3-VRRP_BAD_AUTH: vrid-1 on TenGig 11/12 rcvd pkt with authentication failure.
VRRP_GO_MASTER PROTO NONE
%VRRP-6-VRRP_MASTER: vrid-%d on %s entering MASTER
VRRP_PROTOCOL_ERROR PROTO NONE
VRRP_PROTOERR: VRRP protocol error on %S
BGP4_ESTABLISHED PROTO NONE
%TRAP-5-PEER_ESTABLISHED: Neighbor %a, state %s
BGP4_BACKW_XSITION PROTO NONE
%TRAP-5-BACKWARD_STATE_TRANS: Neighbor %a, state %s
ETS_TRAP_TYPE_MODULE_STATUS_CHA
NGE
ETS NONE
%DIFFSERV-5-ETS_TRAP_TYPE_MODULE_STATUS_CHANGE: ETS Module status changed to enabled
Table 41-1. SNMP Traps and Error Messages (continued)