XSCF>
showpcl
-p
0
PPAR-ID
LSB
PSB
Status
00
Running
(*1)
00
00-0
(*2)
01
01-0
(*3)
 
XSCF>
showboards
-p
0
PSB
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
----
------------
-----------
----
----
----
-------
--------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
(*3)
01-0
00(01)
Assigned
y
y
y
Passed
Normal
(*3)
*1
PPAR
ID#00
is
running.
*2
LSB#00
is
defined
for
PSB#00-0
of
PPAR
ID#00,
and
LSB#01
is
defined
for
PSB#01-0.
*3
PSB#00-0
and
PSB#01-0
are
assigned
to
PPAR
ID#00,
and
both
are
running.
XSCF>
showhardconf
SPARC
M12-2S;
+
Serial:PZ51652009;
Operator_Panel_Switch:Locked;
+
System_Power:On;
System_Phase:Cabinet
Power
On;
Partition#0
PPAR_Status:Running;
BB#00
Status:Normal;
Role:Master;
Ver:4016h;
Serial:PZ51652009;
+
FRU-Part-Number:CA20369-B17X
005AC/9999999
;
+
Power_Supply_System:
;
+
Memory_Size:256
GB;
(Omitted)
BB#01
Status:Normal;
Role:Standby
;
Ver:4016h;
Serial:PZ51651016;
(*1)
+
FRU-Part-Number:CA20369-B17X
005AC/9999999
;
+
Power_Supply_System:
;
+
Memory_Size:1024
GB;
(Omitted)
 
The
following
example
executes
the
commands
for
releasing
BB#01
in
the
2BB
configuration.
To
restore
the
system
after
maintenance
on
the
SPARC
M12-2S,
write
down
the
status
checked
in
steps
1
to
7.
First,
log
in
to
the
XSCF
shell,
and
check
the
hardware
configuration
information
for
the
SPARC
M12-2S
to
be
released.
1.
Check
the
PSB
configuration
and
operation
status
of
the
physical
partition.
The
following
example
assumes
that
the
user
logs
in
to
the
master
XSCF,
checks
the
PSB
configuration,
LSB
number,
and
operation
status
of
PPAR
ID#00,
and
then
checks
the
operation
status
of
the
PSB.
Here,
it
is
assumed
that
BB#01
(PSB#01-0)
will
be
released.
2.
Check
the
status
of
the
XSCF
of
the
SPARC
M12-2S
to
be
released.
The
following
example
assumes
that
the
user
logs
in
to
the
master
XSCF
and
confirms
that
the
XSCF
of
the
SPARC
M12-2S
to
be
released
is
in
the
standby
state
or
is
the
slave
XSCF.
Chapter
9
 
Releasing
FRUs
From
the
System 297

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals