Page #99 background image
Table
4-8
  
Active/Cold
Replacement
Procedure
of
the
XSCFU
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Confirming
the
XSCFU
to
be
replaced "8.2
Troubleshooting"
3 Confirming
that
the
XSCFU
to
be
replaced
is
the
standby
or
slave
XSCF
and
is
currently
replaceable
(*1)
"
Table
2-16
XSCFU
LEDs
and
Their
States"
4 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
5 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
6 Releasing
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
from
a
logical
domain
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
7 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
8 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
9Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state
"9.8.2
Removing
the
Power
Cords"
10 Removing
the
XSCFU
from
the
SPARC
M12-2S
"11.4
Removing
the
XSCFU"
11 Switching
the
SD
card
(*2) "11.5
Switching
an
SD
Card"
12 Installing
the
XSCFU
in
the
SPARC
M12-2S
(*3)
"11.6
Installing
the
XSCFU"
13 Placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
"10.1.1
Installing
a
Power
Cord"
14 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
15 Confirming
that
there
is
no
problem
with
the
replacement
XSCFU
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
16 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
Table
4-8
shows
the
workflow
for
active/cold
replacement
of
the
XSCFU.
Chapter
4
 
FRU
Replacement
Workflows 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals