PROGRAMMING EXAMPLES PAGE 43
B1290: Expander One, Alarm One is...
YOU: Change this voice
B1290: beep-beep
YOU: Intrusion
B1290: Expander One, Alarm One is Intrusion
YOU: Next
B1290: Expander One Alarm Two is...
YOU: Change this voice
B1290: beep-beep
YOU: High Temperature
B1290: Expander One, Alarm Two is High Temperature
YOU: Next
B1290: Expander One, Alarm Three is...
Continue programming in the normal fashion, remembering to enter the number of the expander before the Program
Code. Only the voices MUST be programmed; the other parameters have their standard defaults. Not all
parameters are accessible in the expander. The following is a list of those which may be programmed:
• Voices
• Relay On/Off codes
• Alarm On/Off codes
• Remote alarm input codes
• Alarm format
• Relay On time
• Alarm delay (debounce)
• Expander Site ID enable
If you try to change the parameters in other expanders, the B1290 will announce Error. To solve this problem,
define all of the expanders in the system in the B1290 using program code 7 (number of expanders).
To change the Alarm On code for the first alarm on the second expander, you would program the following (the
example assumes that the number of expanders has already been set to 2 as shown above):
B1290: Enter Program Code
YOU: Expander 2, DTMF Codes
B1290: Enter DTMF Code
YOU: Alarm On/Off Output codes
B1290: Expander Two Alarm One On Code is Empty
YOU: Enter code 9678
B1290: Expander Two Alarm One On Code is 9678
YOU: Next
etc.