Query-interval: 125s
General-query source IP: 1.1.1.1
Special-query source IP: 2.2.2.2
Report source IP: 3.0.0.3
Leave source IP: 1.0.0.1
Dot1p-priority: 2
IGMP snooping information: VLAN 10
IGMP snooping: Enabled
Drop-unknown: Enabled
Version: 3
Host-aging-time: 260s
Router-aging-time: 260s
Max-response-time: 10s
Last-member-query-interval: 1s
Querier: Disabled
Query-interval: 125s
General-query source IP: 1.1.1.1
Special-query source IP: 2.2.2.2
Report source IP: 3.0.0.3
Leave source IP: 1.0.0.1
Dot1p-priority: --
Table 1 Command output
Field Descri
p
tion
IGMP snooping
IGMP snooping status:
Enabled.
Disabled.
Drop-unknown
Status of dropping unknown multicast data:
Enabled.
Disabled.
Version IGMP snooping version.
Host-aging-time Aging timer for the dynamic member port.
Router-aging-time Aging timer for the dynamic router port.
Max-response-time Maximum response time for IGMP general queries.
Last-member-query-interval Interval for sending IGMP group-specific queries.
Report-aggregation
Status of IGMP report suppression:
Enabled.
Disabled.
Dot1p-priority
802.1p priority for IGMP messages. If the priority is not configured,
this field displays two hyphens (--).
Querier Whether the IGMP snooping querier is enabled.
Query-interval Interval for sending IGMP general queries.
General-query source IP Source IP address of IGMP general queries.
2

Table of Contents

Other manuals for HP 5900 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 series and is the answer not in the manual?

HP 5900 series Specifications

General IconGeneral
Ports48x 10/100/1000BASE-T, 4x 10GE SFP+
Switching Capacity1.28 Tbps
MAC Address Table Size128K
Routing ProtocolsRIP, OSPF, BGP, IS-IS
VLAN Support4K VLANs
Dimensions440 x 460 x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (noncondensing)