Parameters
vpn-instance vpn-instance-name: Specifies an MPLS L3VPN instance by its name, a case-sensitive string
of 1 to 31 characters. If you do not specify a VPN instance, you enter public network PIM view.
Examples
# Enable IP multicast routing on the public network and enter public network PIM view.
<Sysname> system-view
[Sysname] multicast routing
[Sysname-mrib] quit
[Sysname] pim
[Sysname-pim]
# Enable IP multicast routing in VPN instance mvpn and enter PIM view of VPN instance mvpn.
<Sysname> system-view
[Sysname] multicast routing vpn-instance mvpn
[Sysname-mrib-mvpn] quit
[Sysname] pim vpn-instance mvpn
[Sysname-pim-mvpn]
Related commands
multicast routing-enable
pim bfd enable
Use pim bfd enable to enable BFD for PIM.
Use undo pim bfd enable to disable BFD for PIM.
Syntax
pim bfd enable
undo pim bfd enable
Default
BFD is disabled for PIM.
Views
Interface view
Predefined user roles
network-admin
Usage guidelines
This command takes effect only when PIM-DM or PIM-SM is enabled on an interface.
Examples
# On the public network, enable IP multicast routing, enable PIM-DM on VLAN-interface 100, and
enable BFD for PIM on the interface.
<Sysname> system-view
[Sysname] multicast routing
[Sysname-mrib] quit
[Sysname] interface vlan-interface 100
[Sysname-Vlan-interface100] pim dm

Table of Contents

Other manuals for HP 5900 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 series and is the answer not in the manual?

HP 5900 series Specifications

General IconGeneral
Ports48x 10/100/1000BASE-T, 4x 10GE SFP+
Switching Capacity1.28 Tbps
MAC Address Table Size128K
Routing ProtocolsRIP, OSPF, BGP, IS-IS
VLAN Support4K VLANs
Dimensions440 x 460 x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (noncondensing)

Related product manuals