EasyManuals Logo

HP 5900 series Command Reference

HP 5900 series
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
Usage guidelines
This command takes effect only on the IPv6 multicast groups that a port joins dynamically.
This command and the mld-snooping overflow-replace command have the same function but different
effective ranges:
The overflow-replace command in MLD-snooping view takes effect on all ports.
The mld-snooping overflow-replace command takes effect on the current port.
For a port, the mld-snooping overflow-replace command takes priority over the overflow-replace
command in MLD-snooping view.
Examples
# Enable the IPv6 multicast group replacement feature globally for VLAN 2.
<Sysname> system-view
[Sysname] mld-snooping
[Sysname-mld-snooping] overflow-replace vlan 2
Related commands
mld-snooping overflow-replace
report-aggregation (MLD-snooping view)
Use report-aggregation to enable MLD report suppression.
Use undo report-aggregation to disable MLD report suppression.
Syntax
report-aggregation
undo report-aggregation
Default
MLD report suppression is enabled.
Views
MLD-snooping view
Predefined user roles
network-admin
Examples
# Disable MLD report suppression.
<Sysname> system-view
[Sysname] mld-snooping
[Sysname-mld-snooping] undo report-aggregation
reset mld-snooping group
Use reset mld-snooping group to remove the dynamic MLD snooping forwarding entries for IPv6
multicast groups.
233

Table of Contents

Other manuals for HP 5900 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 series and is the answer not in the manual?

HP 5900 series Specifications

General IconGeneral
Ports48x 10/100/1000BASE-T, 4x 10GE SFP+
Switching Capacity1.28 Tbps
MAC Address Table Size128K
Routing ProtocolsRIP, OSPF, BGP, IS-IS
VLAN Support4K VLANs
Dimensions440 x 460 x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (noncondensing)