reset mld-snooping statistics
Use reset mld-snooping statistics to clear statistics for the MLD messages and IPv6 PIM hello messages
learned through MLD snooping.
Syntax
reset mld-snooping statistics
Views
User view
Predefined user roles
network-admin
Examples
# Clear statistics for all MLD messages and IPv6 PIM hello messages learned through MLD snooping.
<Sysname> reset mld-snooping statistics
Related commands
display mld-snooping statistics
router-aging-time (MLD-snooping view)
Use router-aging-time to set the global aging timer for dynamic router ports.
Use undo router-aging-time to restore the default.
Syntax
router-aging-time interval
undo router-aging-time
Default
The global aging timer for dynamic router ports is 260 seconds.
Views
MLD-snooping view
Predefined user roles
network-admin
Parameters
interval: Sets an aging timer for dynamic router ports, in the range of 1 to 8097894 seconds.
Usage guidelines
This command and the mld-snooping router-aging-time command have the same function but different
effective ranges:
The router-aging-time command in MLD-snooping view takes effect on all VLANs.
The mld-snooping router-aging-time command takes effect on the current VLAN.
For a VLAN, the mld-snooping router-aging-time command takes priority over the router-aging-time
command in MLD-snooping view.
235

Table of Contents

Other manuals for HP 5900 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 series and is the answer not in the manual?

HP 5900 series Specifications

General IconGeneral
Ports48x 10/100/1000BASE-T, 4x 10GE SFP+
Switching Capacity1.28 Tbps
MAC Address Table Size128K
Routing ProtocolsRIP, OSPF, BGP, IS-IS
VLAN Support4K VLANs
Dimensions440 x 460 x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (noncondensing)