Syntax
mld startup-query-count count
undo mld startup-query-count
Default
The MLD startup query count equals the MLD querier's robustness variable.
Views
Interface view
Predefined user roles
network-admin
Parameters
count: Sets an MLD startup query count in the range of 1 to 255.
Usage guidelines
This command and the startup-query-count command in MLD view have the same function but different
effective ranges:
The startup-query-count command in MLD view takes effect on all interfaces.
The mld startup-query-count command takes effect on the current interface.
For an interface, the mld startup-query-count command takes priority over the startup-query-count
command in MLD view.
Examples
# Set the MLD startup query count to 5 on VLAN-interface 100.
<Sysname> system-view
[Sysname] interface vlan-interface 100
[Sysname-Vlan-interface100] mld startup-query-count 5
Related commands
startup-query-count (MLD view)
mld startup-query-interval
Use mld startup-query-interval to set the MLD startup query interval on an interface.
Use undo mld startup-query-interval to restore the default.
Syntax
mld startup-query-interval interval
undo mld startup-query-interval
Default
The MLD startup query interval equals one quarter of the MLD general query interval.
Views
Interface view
Predefined user roles
network-admin
290

Table of Contents

Other manuals for HP 5900 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 series and is the answer not in the manual?

HP 5900 series Specifications

General IconGeneral
Ports48x 10/100/1000BASE-T, 4x 10GE SFP+
Switching Capacity1.28 Tbps
MAC Address Table Size128K
Routing ProtocolsRIP, OSPF, BGP, IS-IS
VLAN Support4K VLANs
Dimensions440 x 460 x 44 mm
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (noncondensing)

Related product manuals