SmartAXIS Touch User's Manual 1-3
1 About the SmartAXIS
1
General Information for SmartAXIS
1.3 Special Functions for the Touch
This section describes the functions of the Touch.
I/O Related Functions
Catch Input
The catch input allows it to receive short input pulses from sensors without regard to the scan time. A maximum of
four catch inputs can be used.
Input Filter
The input filter can be adjusted according to the width of input signals to reject input noises. Selectable input filter
values to pass input signals are 0 millisecond, and 3 through 15 milliseconds in 1 millisecond increments.
Interrupt Input
The interrupt input can be used to call an interrupt program to respond to an external input that requires a response
faster than the scan time. A maximum of four interrupt inputs can be used. This can only be used when ladder
program is selected as the programming language for control function.
Stop and Reset Inputs
Stop input is a function to stop the ladder program or FBD program operation for the Touch. Reset input is a function
to stop the ladder program or FBD program operation for the Touch and clear the value of control devices. Any input
terminal on the Touch can be designated as a stop or reset input to control the Touch operation.
Analog Input
Analog input of 0 to 10V DC or 4 to 20 mA can be converted to a digital value of 0 to 1000. A maximum of two inputs
can be used as analog inputs.
Analog Output
Analog output converts a digital value between 0 and 1000 to analog value of 0 to 10V DC or 4 to 20 mA and outputs
it. A maximum of two outputs can be used as analog outputs.
Remote I/O
When the number of Touch inputs and outputs is insufficient, the number of inputs and outputs can be expanded to
a maximum of 156 points by connecting the SmartAXIS Pro/Lite as remote I/O slaves. With the remote I/O function,
the analog inputs on the SmartAXIS that are connected as remote I/O slaves can also be used.
Expanded Analog I/O
Expanded analog I/O allows the Touch to handle analog inputs for voltage, current, thermocouples, and Resistance
thermometer outputs for voltage and current by using analog cartridges. The Touch can be expanded to a maximum
of four analog inputs and outputs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SmartAXIS Touch FT1A Series and is the answer not in the manual?

IDEC SmartAXIS Touch FT1A Series Specifications

General IconGeneral
BrandIDEC
ModelSmartAXIS Touch FT1A Series
CategoryController
LanguageEnglish

Related product manuals