SmartAXIS Touch User's Manual 3-19
3 Project Settings Dialog Box
3
Project
This section describes items and buttons on the Project Settings dialog box.
3.1 System Tab
The System tab is used to configure Touch operations.
Screen No. Format
Selects the type of data to use for the System Area 1 Display screen number (address+0) as BCD or BIN.
Start Time (sec)
Specifies the time from when the Touch power is turned on until communications start with the external device (0 to
9999 seconds).
Auto Backlight OFF
Select this check box to turn off the backlight when the Touch is untouched for an extended period of time. To turn
on the backlight, touch the screen or write 1 to System Area 1 Auto Backlight OFF bit (address+1, bit 5) or System
Area 1 Screen display bit (address+1, bit 7).
3 Project Settings Dialog Box
Default Screen: Specifies the screen number of the Base Screen to display first when the Touch is turned on (0 to
3000). When 0 is specified, the Touch is in the screen waiting state. Write a screen number to
System Area 1 Display screen number (address+0) or specify the default screen number from 1 to
3000.
Time (min): Specifies the time from when the Touch is last used to when the backlight is
turned off (1 to 9999).
Light ON with Screen Changing: When the backlight is turned off with this function, select this check box to turn on
the backlight when the screen is switched.
This option can only be configured when the Auto Backlight OFF check box is
selected.