3 Data Log Settings Dialog Box
14
Data Log Function
■ Edit
Registers or changes the settings for the selected channel number.
Select a channel number, and then click this button to display the Individual Settings dialog box. The settings for the
selected channel are reflected in the Individual Settings dialog box.
For details, refer to “3.2 Individual Settings Dialog Box” on page 14-14.
■ Up
Shifts the selected settings upward in the list.
■ Down
Shifts the selected settings downward in the list.
■ Clear Log Data
Select this check box to erase the data saved in the data storage area.
■ Number of Stored Data for Data Log per Device
Shows the maximum amount of data storage per device for Data Log data saved in the data storage area. If data is
saved up the maximum amount and then the maximum is exceeded, the old data is deleted and the new data is saved.
The default is 0.
Click to display the Data Storage Area Management dialog box where you can change the allocation of data
storage area memory. For details, refer to Chapter 16 “Data Storage Area” on page 16-1.
*1 Advanced mode only
Monitor: Shows the write destination device for the amount of data when monitoring the amount of
sampled data. Shows No when not monitoring. Double clicking the cell displays the Individual
Settings dialog box where you can edit the settings. For details, refer to “3.2 Individual Settings
Dialog Box” on page 14-14. This option can only be set when Enable is selected in Log
Function.
Batch: Shows the trigger device that triggers batch output when batch outputting all the data saved in
the data storage area to the external memory. Shows No when there is no batch output. Double
clicking the cell displays the Individual Settings dialog box where you can edit the settings. For
details, refer to “3.2 Individual Settings Dialog Box” on page 14-14.
Real Time: Shows whether or not to perform real time output. Double clicking the cell switches between
Yes and No. Data is output to the external memory in 3 minute intervals for Yes channels. This
option can only be set when Enable is selected in Log Function.
No. of Data
*1
:
Shows the number of devices to sample in a channel. Double clicking the cell displays the
Individual Settings dialog box where you can edit the settings. For details, refer to “3.2
Individual Settings Dialog Box” on page 14-14. This option can only be set when Enable is
selected in Log Function.
(Trigger device): Specifies the bit device that triggers the erasure of the data. The data for all channels is erased
when the value of the configured device changes from 0 to 1. For the device address
configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-62.