EasyManuals Logo
Home>Edge-Core>Network Router>ES3528MV2

Edge-Core ES3528MV2 User Manual

Edge-Core ES3528MV2
1480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #517 background imageLoading...
Page #517 background image
C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 517 –
SNMP traps can also be configured to provide an automated method of
fault notification. If the fault notification generator detects one or more
defects within the configured time period, and fault alarms are enabled, a
corresponding trap will be sent. No further fault alarms are sent until the
fault notification generator has been reset by the passage of a configured
time period without detecting any further faults. Upon receiving a fault
alarm, you should inspect the related SNMP objects for the reporting MEP,
diagnose the fault, correct it, and re-examine the MEP’s SNMP objects to
see whether the fault notification generator has been reset.
Configuration Guidelines
1. Configure the maintenance domains with the MD List (see "Configuring
CFM Maintenance Domains").
2. Configure the maintenance associations with MA List (see "Configuring
CFM Maintenance Associations").
3. Configure the local maintenance end points (MEPs) which will serve as
the domain service access points for the specified maintenance
association using the MEP List (see "Configuring CFM Maintenance
Associations").
4. Enter a static list of MEPs assigned to other devices within the same
maintenance association using the Remote MEP List (see "Configuring
Remote Maintenance End Points"). This allows CFM to automatically
verify the functionality of these remote end points by cross-checking
the static list configured on this device against information learned
through continuity check messages.
5. Enable CFM globally on the switch using the Configure Global screen
(see "Configuring Global Settings for CFM").
6. Enable CFM on the local MEPs using the Configure Interface screen (see
"Configuring Interfaces for CFM").
7. Enable continuity check and cross-check operations, and configure AIS
parameters using the Configure MA – Configure Details screen (see
"Configuring CFM Maintenance Associations").
Other configuration changes may be required for your particular
environment, such as adjusting the interval at which continuity check
messages are sent (see "Configuring CFM Maintenance Associations"), or
setting the start-up delay for the cross-check operation (see "Configuring
Global Settings for CFM"). You can also enable SNMP traps for events
discovered by continuity check messages or cross-check messages (see
"Configuring Global Settings for CFM").
CONFIGURING GLOBAL
SETTINGS FOR CFM
Use the Administration > CFM (Configure Global) page to configure global
settings for CFM, such as enabling the CFM process on the switch, setting
the start-up delay for cross-check operations, configuring parameters for
the link trace cache, and enabling traps for events discovered by continuity
check messages or cross-check messages.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ES3528MV2 and is the answer not in the manual?

Edge-Core ES3528MV2 Specifications

General IconGeneral
BrandEdge-Core
ModelES3528MV2
CategoryNetwork Router
LanguageEnglish

Related product manuals