EasyManua.ls Logo

Edge-Core ES3528MV2 - Sflow Polling Instance

Edge-Core ES3528MV2
1480 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C
HAPTER
23
| Flow Sampling Commands
– 805 –
This example shows how to modify the sFlow port number for an already
configured collector.
Console(config)#sflow owner stat_server1 timeout 100 port 35100
Console(config)#
sflow polling
instance
This command enables an sFlow polling data source, for a specified
interface, that polls periodically based on a specified time interval. Use the
no form to remove the polling data source instance from the switch’s sFlow
configuration.
SYNTAX
sflow polling {interface interface} instance instance-id
receiver owner-name polling-interval seconds
no sflow polling {interface interface} instance instance-id
interface - The source from which the samples will be taken at
specified intervals and sent to a collector.
ethernet unit/port
unit - Stack unit. (Range: 1)
port - Port number. (Range: 1-28)
instance-id - An instance ID used to identify the sampling source.
(Range: 1)
owner-name - The associated receiver, to which the samples will be
sent. (Range: 1-30 alphanumeric characters)
polling-interval - The time interval at which the sFlow process
adds counter values to the sample datagram. (Range: 0-10000000
seconds, 0 disables this feature)
DEFAULT SETTING
No sFlow polling instance is configured.
COMMAND MODE
Privileged Exec
COMMAND USAGE
This command enables a polling data source and configures the interval at
which counter values are added to the sample datagram.
EXAMPLE
This example sets the polling interval to 10 seconds.
Console(config)#interface ethernet 1/9
Console(config-if)#sflow polling-interval 10
Console(config-if)#