C
HAPTER
20
| System Management Commands
Banner Information
– 703 –
banner configure
dc-power-info
This command is use to configure DC power information displayed in the
banner. Use the no form to restore the default setting.
SYNTAX
banner configure dc-power-info floor floor-id row row-id
rack rack-id electrical-circuit ec-id
no banner configure dc-power-info [floor | row | rack |
electrical-circuit]
floor-id - The floor number.
row-id - The row number.
rack-id - The rack number.
ec-id - The electrical circuit ID.
Maximum length of each parameter: 32 characters
DEFAULT SETTING
None
COMMAND MODE
Global Configuration
COMMAND USAGE
Input strings cannot contain spaces. The banner configure dc-power-
info command interprets spaces as data input boundaries. The use of
underscores ( _ ) or other unobtrusive non-letter characters is suggested
for situations where white space is necessary for clarity.
EXAMPLE
Console(config)#banner configure dc-power-info floor 3 row 15 rack 24
electrical-circuit 48v-id_3.15.24.2
Console(config)#
banner configure
department
This command is used to configure the department information displayed
in the banner. Use the no form to restore the default setting.
SYNTAX
banner configure department dept-name
no banner configure department
dept-name - The name of the department.
(Maximum length: 32 characters)